bstract of Road Light Gateway
In this paper, we have developed the gateway for multi-information
convergence system in ubiquitous sensor network. The gateway gathers the
various sensor data from a road light device, and the data is
transmitted into an energy management system. The sorts of data are the
intensity of illumination, humidity and diagnostic results.In today’s
world of ever-expanding technology, Road Light Gateway is going to
change the whole world of consumer electronics and form the principal
root for the major advancement in the design of electronic circuits and
manufacture of printed circuit boards (PCB).The era of polymer
electronics has taken a great start and all the technological companies
have turned their entire research towards Road Light Gateway. We hope
that, in the forthcoming years Road Light Gateway will accelerate the
pace of the technological advancements and describe a new dimension in
the near future
In recent, a light source of road lamp equipment is replaced by LED
type. In order to save the power consumption, the research of light
source has progressed for various areas.The growth of the digital
technology and an internet made us to merge the LED, sensor and
information technology. The advantage of LED can reduce the power
consumption and an interface the LED with a sensor could have as well
management as control of energy [1].The convergence of such a LED and
sensor based on an information technology provides more many
opportunities to vendors and clients. The one is realized for home
network or outdoor road light system
Introduction
Introduction
The important study for this convergence system is an intelligent
of the integrated devices. In order to implement the road lamp of LED
type with sensor by network, we are interconnecting between lamp posts,
which can integrate the platform of various LED device, sensor hardware
specification and dimmer function [3].
In this paper, we use the ad-hoc network technology to integrate
the lamp posts. The gathered data by sensor networking is transmitted
into EMS through the gateway. Also, we use wireless technology to
transmit the gathered data among LED lamp posts. Finally, the data is
transmitted into an EMS center, and then we use the CDMA technology. The
EMS center can monitor variously the data obtained
In order to supply a voltage source, we use electronic ballasts
that are composed of drive circuit, multivibrator, protection circuit
and output parts. An external ac, 220 V input signal for driving the
ballasts is connected to the circuit, and then drive the oscillator and
the switching circuit.
The variable resistor of an oscillator can control the pulse width of signal and the driving speed. By doing these operation, the electronic ballasts can control the output voltage and current of a transformer .
The period of pulse use 0.5s, the stabilized high voltage in the rectifier circuit drives the transformer. If we add output load (or neon tube) to electronic ballasts, the overvoltage protection circuit isn’t operating. But if the electronic ballasts have no load, it stops the high voltage by holding the output signal of oscillator
UART#1 is connected to the sensor network devices with 900 MHz and
UART#2 is connected to the sensor network devices with 2.4 GHz. OS use
an Embedded Linux. Figure 4 shows the diagram of the gateway. This
gateway communicates with smart meter and CMDA module. The one transmits
the control command into monitoring management system [8].
The output characteristics of the PECL VCXO have a complementary type, sustain the valence to the output impedance and transmission delay. Unless, the zero cross point both output signal is changed and leads an asymmetric characteristics of the signal waveform
It is necessary for studying the chip to minimize the power and size of gateway. In the future, we must research for the data communication method of Ad-hoc network among the LED lamp posts in order to growth up the real time process and an efficiency of the network.
The Gateway For Light Sensor
A sensor device has been used in road lamp system and the
information of the sensors is transmitted into the control box through
the gateway device. It controls the distributed box for control the lamp
management system, reversely. Figure 2 shows the structure of sensor
network for implementing the gateway [5].The sorts of the sensors use
CO2 sensor, intensity of illumination for measuring the light level and
the humidity.
The gateway of the sensor network exists between sensor node devices
and the monitoring system. The gateway handles various sensing
information obtained from sensor node.The variable resistor of an oscillator can control the pulse width of signal and the driving speed. By doing these operation, the electronic ballasts can control the output voltage and current of a transformer .
The period of pulse use 0.5s, the stabilized high voltage in the rectifier circuit drives the transformer. If we add output load (or neon tube) to electronic ballasts, the overvoltage protection circuit isn’t operating. But if the electronic ballasts have no load, it stops the high voltage by holding the output signal of oscillator
Structure Of The Gateway
The gateway of implementing in this paper are
composed of ARM7 core of RISC families, a processor compatible with
communication hub or router, 4MB(x2) flash ROM, 16MB(x2) SDRAM,
10/100based Ethernet and two serial port with sensor nodes and CDMA
module. Also, the one supports 4 UART serial interface and wireless
Zigbee. The main processor operates in 50 MHz, the Ethernet transceiver
operates in 25 MHz. Two systems are connected with DMA (data memory
access), use DMA interrupts and detect physically 10 Mbps or 100 MbpsThe output characteristics of the PECL VCXO have a complementary type, sustain the valence to the output impedance and transmission delay. Unless, the zero cross point both output signal is changed and leads an asymmetric characteristics of the signal waveform
Conclusion and Future Scope
In this paper, we have developed the gateway that can interconnect
between EMS center and the lamp post using the CDMA. The sensor node
among road lamp posts can gather the various data like the intensity of
illumination of LED, humidity and CO2. The one is transmitted into an
EMS center through the gateway.It is necessary for studying the chip to minimize the power and size of gateway. In the future, we must research for the data communication method of Ad-hoc network among the LED lamp posts in order to growth up the real time process and an efficiency of the network.
References
[1] www.uClinux.org [2] www.m2mkorea.co.kr
[3] www.ledsmps.com
[4] Y. Rekhter, B. Moskowitz, D. Karrenberg and G. de Groot, “Address Allocation for Private Internets”, T. J. Watson Research Center, IBM Corp., Chrysler., RIPE NCC, RFC 1597, March 1994
[5] R. Droms, “Dynamic Host Configuration Protocol”, RFC 1541, Bucknell University, Oct. 1993
[6] F. Akyidiz et al., “A Survey on Sensor Networks”, IEEE Communication Magazine, Vol.40, No.8, pp.102-114, Aug. 2002
[7] www.maximalight.com
[8] B. Heinzelman et al., “An Application –specific Protocol Architecture for Wireless Micro sensor Networks”, IEEE Trans. On Wireless Communications, Vol.1, No.4, pp.660 -670, Oct. 2002
[9] http://www.cablemodem.com, Cable Labs
No comments:
Post a Comment